low sharpness, low squaremeter

Phenomenon: the cutting machine down less, the main motor current increases, the cutting feeding speed is slow, even saw blade appear noise and shaking.

Reason 1 The concentration of diamond powder is too high.

Reason 2 Power supply voltage is too low (below 360V).

Reason 3 cutting machine power is too small (below 22KW).

Reason 4 matrix is too soft or uneven, shaking.

Reason 5 cutting machine belt shake with more than one tie.

Reason 6 stone base support is not stable.

Resaon 7 The coolant is too thick.

Reason 8 cutting machine spindle bearing shaking or tough

Reason 9 cutting depth is too high